@Article{HasarBaKaErBuCa:2014:TwNuPr,
               author = "Hasar, Ugur Cem and Barroso, Joaquim Jos{\'e} and Kaya, Yunus and 
                         Ertugrul, Mehmet and Bute, Musa and Catal{\'a}-Civera, Jos{\'e} 
                         M.",
          affiliation = "{University of Gaziantep} and {Instituto Nacional de Pesquisas 
                         Espaciais (INPE)} and {Bayburt University} and {Ataturk 
                         University} and {University of Gaziantep} and {Universitat 
                         Polit{\`e}cnica de Val{\`e}ncia}",
                title = "Two-step numerical procedure for complex permittivity retrieval of 
                         dielectric materials from reflection measurements",
              journal = "Applied Physics A: Material Science and Processing",
                 year = "2014",
               volume = "114",
                pages = "1--10",
                 note = "Setores de Atividade: Fabrica{\c{c}}{\~a}o de equipamentos de 
                         inform{\'a}tica, produtos eletr{\^o}nicos e {\'o}pticos. and 
                         {Informa{\c{c}}{\~o}es Adicionais: Article number 8303.}",
             keywords = "permittivity, retrieval of permittivity and permeability, 
                         reflection measurement.",
             abstract = "A two-step measurement procedure has been proposed for measurement 
                         of complex permittivity of dielectric materials using one-port 
                         reflection measurements. In the procedure, as a first step, a 
                         graphical method is applied to analyze on the complex 
                         reflection-coefficient plane the general pattern of dielectric 
                         behavior of the sample. Then, as a second step, optimization 
                         algorithms are utilized for retrieving electrical properties of 
                         samples. The procedure requires measurement of complex reflection 
                         scattering parameters of at least two samples with different 
                         lengths. It has been validated by X-band measurements of three 
                         polyvinyl chloride samples with lengths 5, 10, and 20 mm.",